Mirror Demisters for Bathrooms by WarmFloors

 

>Technical Information<

ELECTRIC CONNECTIONS & SAFETY INFORMATION

All wiring must conform to the latest IEE wiring regulations (BS7671 equivalent) if in doubt always consult a qualified electrician.

Mirror Demisters - For Clear Mirrors in Bathrooms
Country Information
UK + EC Coplies with the Low Voltage Electrical Equipment (Safety) Regulations 1989 to BS 3456 and the European Standard EN 60335-2-30, 1993, as tested by SGS UK Ltd (NAMAS accredited test body)
USA Approval No. E 151390 issued by Underwriters Laboratoried Inc.
Australia Dept. of energy Certification No.CS 6970N to the Electrical safety requirements.
Necessities and Recommendations
Technical Specifications

- It is recommended that the demister pad is connected via the lighting circuit or on a separate switch.
- The circuit should be protected by a 5amp fuse or circuit breaker
- The Demister pad must not be accessible once installed
- Any metal part surrounding the mirror must be earthed & comply with current wiring regulations
- Multiple pads may be fitted to a single mirror & should be connected in parallel
- Pads must not overlap
- The demister pad must not be cut or pierced as this may damage the insulation making it unsafe

- Depth of terminal block - H 6mm x W 20mm x L 15mm
- Pad thickness - Less than 1 mm (700 micrometers)
- 1 Meter twin core 0.5mm oval cable
- Uniform mat of reinforced glass fibre substate impregnated with conductive carbon.
- Double insulated, multi-layer Polymer to 10 Kv
- Power Rating - 200 Watt/sq m
Other Information
- Low surface temperature.
- Running costs are almost insignificant - 32 hours for 1p! It also saves on time and cleaning materials.
- The Pads are self adhesive, fits to the back of virtually any mirror - new or existing - or to the wall, and simply wires into the bathroom lighting in accordance with instructions
- The demister pads... can also be connected to the fan or seperate switch if preferred.
- 5 year warranty against any manufacturing fault, providing the pad is fitted strictly in accordance with intructions supplied.